CJKVF - H6682 NICAD BATTERY, SEALED

  • MSDS: CJKVF
  • Manufacturer: ALEXANDER MFG CO
  • Product Name: H6682 NICAD BATTERY, SEALED
  • National Stock Number: 6140-00-476-8797
Product Identification

Product ID:H6682 NICAD BATTERY, SEALED
MSDS Date:02/01/1994
FSC:6140
NIIN:00-476-8797
Status Code:A
MSDS Number: CJKVF

Responsible Party
ALEXANDER MFG CO.
1511 S. GARFIELD PL
MASON CITY, IA 50401-5662
US

Emergency Phone: 515-423-8955

Info Phone: 515-423-1161

Preparer: CANNOT READ SIGNATURE

Cage: 56469

Contractor
ALEXANDER TECHNOLOGIES INC
1508 MASON CITY, IA 50401 US

Telephone: 515-423-1161/8955

Cage: 56469

Ingredients

NICKEL & NICKEL HYDROXIDE

CAS: 7440-02-0

RTECS: QR5950000

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3


CADMIUM & CADMIUM HYDROXIDE

CAS: 7440-43-9

RTECS: EU9800000

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


POTASSIUM HYDROXIDE

CAS: 1310-58-3

RTECS: TT2100000

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ALEXANDER MFG. CO. CONSIDERS THIS
BATTERY AN "ARTICLE" AS DEFINED IN 29 CFR 1910-1200 SECTION(C).
FURTHER, THIS ARTICLE (BATTERY) DOES NOT RELEASE OR OTHERWISE
RESULT IN EXPOSURE TO A HAZARDOUS CHEMIC AL UNDER THE CONDITIONS OF
YOUR INTENDED USE. EACH CELL OF THE BATTERY IS A SEALED CONTAINER
ENCLOSING A NICKEL ELECTRODE, A CADMIUM ELECTRODE & POTASSIUM
HYDROXIDE ELECTRODE.
Effects of Overexposure:NOTE: UNDER NORMAL USE, H6682 DOES NOT RELEASE
TOXIC MATERIAL. INHALATION-DURING A FIRE INVOLVING LARGE QUANTITIES
OF BATTERIES, CADMIUM FUMES MAY BE RELEASED. EYE-IF BATTERY
RUPTURES, SKIN CONTACT MA Y COME IN CONTACT WITH TRACE AMOUNT OF
POTASSIUM HYDROXIDE, WILL CAUSE A BURN. SKIN-IF BATTERY RUPTURES,
SKIN CONTACT MAY COME IN CONTACT WITH TRACE AMOUNT OF POTASSIUM
HYDROXIDE WILL CAUSE A BURN.

Fire Fighting

Extinguishing Media:NO INFO AVAILABLE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS IF
LARGE QUANTITIES OF BATTERIES ARE ON FIRE. WAREHOUSE OR DEPOT TYPE
STORAGE.
Unusual Fire/Explosion Hazard:CADMIUM FUMES MAY BE RELEASED DURING
BURNING.

Accidental Release

Spill Release Procedures:ELECTROLYTE, POTASSIUM HYDROXIDE IS CAUSTIC.
DO NOT ALLOW SKIN OR EYE CONTACT. FLUSH WITH WATER. THERE IS ONLY A
TRACE AMOUNT OF POTASSIUM HYDROXIDE AVAILABLE IN THE BATTERY.

Handling

Handling and Storage Precautions:DO NOT INCINERATE OR MUTILATE; MAY
BURST RELEASING TOXIC MATERIAL, (CADMIUM FUMES).
Other Precautions:DO NOT SHORT CIRCUIT BATTERY, IT MAY CAUSE BURNS WHEN
IN CONTACT WITH THE SKIN OR EYES.

Exposure Controls

Supplemental Safety and Health

Chemical Properties

HCC:Z7

Stability

Stability Indicator/Materials to Avoid:YES
NO INFO AVAILABLE.
Stability Condition to Avoid:BURNING (FIRE), RUPTURING.
Hazardous Decomposition Products:CADMIUM FUMES MAY BE RELEASED DURING A
FIRE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE &
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.